Wuhan Lanxun Square Cooling Tower HMK-300L
video
Wuhan Lanxun Square Cooling Tower HMK-300L

Wuhan Lanxun Square Cooling Tower HMK-300L

Wuhan Lanxun Square Cooling Tower

Description

Model HMK-300L

product-1155-1223

Water flow rate 300 m*/h
External dimensions L5600*W3500*(H3500+tower cap 1400)
Inlet DN 150*2
Outlet DN200
Production Date: 2018.07

 

Lower Condensing Temperatures: Cooling towers cool water by taking advantage of the latent heat of evaporation, which is a very efficient process. This allows them to reject heat to a lower temperature (the ambient wet-bulb temperature) than an air-cooled system can (which is limited by the higher ambient dry-bulb temperature).

Reduces Chiller Workload: In a chiller system, the lower the temperature of the water coming into the condenser, the less hard the chiller's compressor has to work. This dramatically reduces electricity consumption. Water-cooled chiller systems with cooling towers typically operate at 0.5-0.6 kW/ton, compared to 0.9-1.3 kW/ton for air-cooled systems.

Significant Cost Savings: For large facilities running 24/7 (like data centers or hospitals), this efficiency translates into massive annual savings on electricity bills.

Greater Capacity and Scalability

Handles Large Heat Loads: Cooling towers are exceptionally effective at rejecting very large amounts of heat in a relatively compact footprint. This makes them the only viable solution for large office buildings, power plants, refineries, and data centers.

Stable Performance in High Ambients: While efficiency does drop on hot, humid days, the performance drop is less severe than with air-cooled systems. A cooling tower's output is based on wet-bulb temperature, which is generally lower and more stable than the dry-bulb temperature that air-cooled systems depend on.

Longer Lifespan for Primary Equipment

Protects the Chiller: By providing a stable stream of cool condenser water, the cooling tower allows the chiller to operate under optimal, less stressful conditions. This reduces wear and tear on the compressor and other components, significantly extending the life of the expensive central chiller (often 20+ years, compared to 15-20 for air-cooled).

Flexibility in Location and Footprint

Chiller Indoors, Tower Outdoors: The system is split. The noisy, bulky chiller can be located in an interior mechanical room, saving valuable exterior or roof space for other uses.

Smaller Chiller Footprint: Because the condenser is water-cooled and doesn't require a large coil and fan array, the chiller unit itself is more compact than an equivalent air-cooled chiller.

Towers Can Be Versatile: Cooling towers can be installed on rooftops, at grade level, or even as part of a building's architectural design. There are various types (crossflow, counterflow) to fit different space constraints.

Cost-Effectiveness for Large Systems

Lower Initial Cost per Ton of Cooling: For systems larger than approximately 400 tons, the combined cost of a water-cooled chiller and a cooling tower is often lower per ton than installing an air-cooled chiller system. This, combined with the massive operational savings, makes the lifecycle cost far superior.

Hot Tags: wuhan lanxun square cooling tower hmk-300l, China wuhan lanxun square cooling tower hmk-300l suppliers, factory, Cooling Tower HKD 616 FL C3, Cooling Tower KHY 150L, Cooling Tower KHY 250L, Cooling Tower KSD LN 675RT, Cooling Tower LRC H 700, Cooling Tower NX1025PAN2FPK

You Might Also Like